- Luanda · Angola
- Fire detection & suppression
Fire protection, from design to maintenance.
We design, install, commission and maintain fire detection and suppression systems in Angola, onshore and offshore.

- Founded
- 2024 · Luanda
- Commissioning
- SAQCC certified
- Design
- To NFPA standards
- Operations
- Onshore and offshore
01How it works
How a protected room puts out a fire.
A gas suppression system, from the first detector to discharge. This is what we design, install and test.
-
Stage 1 / 4
Normal
The system is armed. Detectors and VESDA aspiration sample the air continuously, and the control panel supervises every circuit, day and night.

Panel · extinguishing control - Detection
- Smoke, heat and aspiration
- Supervision
- 24 hours
-
Stage 2 / 4
Detection
A first detector goes into alarm. The panel goes into pre-alarm and warns the occupants. In a typical system, one detector alone does not release the gas.

VESDA · aspirating detection - Pre-alarm
- Warning, no discharge
- Aspiration
- VESDA
-
Stage 3 / 4
Alarm and delay
A second detector confirms the fire. Sounders and beacons call for evacuation and the pre-discharge delay begins, typically 30 seconds, so everyone can leave the room.

Ziton ZP3 · extinguishing control unit - Confirmation
- 2 detectors
- Delay
- Typically 30 s
-
Stage 4 / 4
Discharge
The cylinders release the agent through the nozzles. FM200 (HFC-227ea) discharges within 10 seconds and puts the fire out without water or damage to the equipment. Inert gas systems discharge in one to two minutes.

FM200 · cylinder bank - FM200
- Within 10 s
- Inert gas
- 60–120 s
- Water
- None
Need to protect a server or plant room?
Talk to us on WhatsApp02Services
A complete fire protection service.
From the first survey to routine maintenance, we look after the whole system so it works on the day it is needed.
Detect and warn

- 01
Fire detection
Alarm panels, smoke and heat detectors and aspirating detection (VESDA) that raise the alarm early, so action can be taken before a fire grows.
- 02
Voice evacuation
Loudspeaker systems for emergency announcements by floor, group of floors, stairwell or car park.
Suppress and contain

- 03
Gas suppression
FM200 and inert gas systems for server rooms, communications rooms and electrical switchrooms. They put out fire without water and without damaging equipment.
- 04
Sprinklers & hose reels
Sprinkler networks, hose reels and hydrants, with pumps and pipework sized for each building.
- 05
Fire extinguishers
Supply, installation and maintenance of portable extinguishers matched to each type of risk.
- 06
Passive firestopping
Sealing openings and joints in fire-rated walls and floors to stop fire and smoke from spreading.
Maintain and deliver

- 07
Maintenance & inspections
Alarm testing, pressure checks, sprinkler head cleaning and panel checks on a six-monthly and annual plan.
- 08
Complete projects
Design, planning, procurement, installation, inspection, quality control and handover, in Angola and abroad.
- 09
Training
Hands-on training for system users and for fire brigades.
One project, five steps
- 01
Design
Site visit, risk assessment and system design.
- 02
Planning
Scheduling the work and choosing the equipment.
- 03
Installation
Supplying, fitting and connecting the whole system.
- 04
Inspection
Testing, commissioning and quality control.
- 05
Maintenance
Routine checks so the system stays ready.
Tell us the building and the system you need.
Request a quote03Installations
Installation record.
Equipment installed and commissioned by our team.
Inert cylinder bank
FM200 two-cylinder system
Pumps fire pump room
Hose reel reel and extinguisher station
CO2 cylinder cabinet
Alarm extinguisher and alarm bell
04Maintenance
A system only protects you if it works.
Regular inspections keep sprinkler heads and escape routes clear and confirm the alarm panel has no faults. This is the usual plan:
Request a maintenance plan- Every 6 months
- Fire alarms, smoke detectors and emergency lighting
- Annual
- Hoses, hydrants and fire extinguishers
- As needed
- Escape routes and emergency exits
- Weekly, on request
- Support with weekly alarm tests
Brands and suppliers we work with
Ziton ZP3Xtralis VESDAFM200Pinnsec · InergenTycoScott Safety (SCBA & EEBD)Ansul
05Engineering
Beyond fire.
The same team delivers civil works and building services, from foundations to finishes.

Pool pool and jacuzzi

Water electrofusion welding unit

House under construction
Planning a build, a pool or HVAC work?
Talk to us on WhatsApp06About us
A new company with an experienced team.
N'JEPELE – Engenharia e Serviços, Lda was founded in 2024 in Luanda. The team brings nearly a decade of experience in the onshore and offshore industry.
Our director holds a degree in Mechatronic Engineering and is an SAQCC-certified commissioner for fire and gas systems.
To protect lives, property and the environment with efficient, safe and innovative fire prevention and firefighting solutions, delivered with technical rigour, regulatory compliance and a commitment to sustainability.
- Founded
- 2024
- Based
- Luanda, Angola
- Leadership
- Mechatronic Engineering degree · SAQCC commissioner
- Sectors
- Industrial · Commercial · Residential
- Operations
- Onshore and offshore
- Values
- Reliable · Durable · Guaranteed

07Contact
Tell us what you need to protect.
Quotes, site visits or maintenance: reach us on whichever channel suits you.
Chat on WhatsApp- Phone · Angola
- +244 934 908 934
- Phone · South Africa
- +27 72 173 6564



